With a budget of only eight cups of tea liquor, how should temperature and extraction time be arranged to provide as much information as possible for fitting a quadratic model? Here we first specify the allowable combinations of temperature and time, and then choose eight distinct points from them. Each cup uses 1.00 g of tea from the same batch, 100 mL of water from the same batch, and the same container, stirring, filtration, and reading protocol; the response is the absorbance of the clarified tea liquor at 420 nm.

Fix the Candidate Points and the Model First

The candidate temperature levels are 60, 65, 70, 75, and 80 °C, and the times are 1, 3, and 5 min. Let A = (temperature − 70)/10 and B = (time − 3)/2, and specify in advance that the operating region for this round is A + B ≤ 1. Combining the five temperatures with the three times one by one and then filtering by this condition gives 13 allowed candidate points; 75 °C with 5 min and 80 °C with 5 min are not included in this round. This is a range chosen in advance for this plan.

Temperature Allowed times
60 °C 1, 3, 5 min
65 °C 1, 3, 5 min
70 °C 1, 3, 5 min
75 °C 1, 3 min
80 °C 1, 3 min

The model to be fitted is fixed before choosing points: Y = β₀ + β₁A + β₂B + β₃A² + β₄AB + β₅B² + ε, where Y is the absorbance at 420 nm. The six coefficients correspond to the intercept, two linear terms, two squared terms, and the interaction term. Each candidate point is written as one row [1, A, B, A², AB, B²] in the same order; the eight selected rows form the design matrix X.

The D-optimality criterion searches among these combinations for the design that maximizes det(X′X). For independent, homoscedastic errors in a linear model, this is equivalent to minimizing the generalized variance of the covariance matrix of the parameter estimates in the pre-specified model. Point selection therefore depends on the model: change the model first, and only then talk about the optimal design. [1]

This plan chooses 8 distinct points from the 13, enumerating all C(13,8) = 1287 subsets one by one, checking the rank of each design matrix and computing the log of the determinant with slogdet. The result is 1240 full-rank subsets and 47 rank-deficient subsets; the unique maximum corresponds to det(X′X) = 1008, with matrix rank 6. The optimality here applies only to the search space of these 13 candidate points, the six-term model above, eight runs, and selection without repeated points.

Left: candidate temperature–time points and the run numbers of the selected ones. Right: the distribution of the log determinant over the enumerated subsets

An actual enumeration of choosing 8 distinct points from the 13 pre-specified allowed candidate points. The left panel shows the tea extraction plan with randomized run numbers; the right panel shows the full-rank log det distribution over all 1287 subsets; the quadratic model chosen has rank 6. The figure illustrates the design calculation; it is not a measurement of extraction absorbance, and it does not claim a global optimum over the continuous region.

Run the Eight Cups in Random Order

Once the combination is chosen, randomize its order to reduce the risk that run order systematically coincides with temperature or time. [1] The order below was generated with random seed 20261125; each row is a separately prepared fresh sample.

Run order Temperature (°C) Extraction time (min) A B
1 60 3 −1 0
2 80 3 1 0
3 70 1 0 −1
4 70 5 0 1
5 60 5 −1 1
6 70 3 0 0
7 80 1 1 −1
8 60 1 −1 −1

Temperature and time are the independent variables that are actively changed; the batch, amount, container, stirring, and filtration of the tea and water are kept consistent. The eight cups use different combinations, and the effects of temperature and time are assessed by comparing them with one another; no separate control treatment without tea leaves is set up. During measurement, a water blank with the same path length is used to correct the instrument baseline; the water blank does not substitute for a tea-liquor treatment.

Uniform Sample Preparation and Measurement

Before starting, calibrate the water-bath temperature, the timer, and the spectrophotometer, and settle the same stirring method for every cup, the stopping and clarifying-filtration steps after extraction, and the conditions for reading after cooling. Specify in advance the reading range the instrument is suited to and a uniform dilution rule for readings outside that range, and prepare the record sheet. The temperature and time settings belong to this experimental plan.

Prepare each cup fresh, in the order in the table: weigh 1.00 g of tea from the same batch, add 100 mL of water from the same batch, and extract at the water-bath temperature and for the time specified in that row. At the end of the time, immediately stop the extraction, filter, and cool in the predetermined, uniform way; when dilution is needed, follow the predetermined rule and record the dilution factor. Using a cuvette of the same path length and the water blank, read the absorbance of the clarified tea liquor at 420 nm.

For each cup, record the run order, the target and actual temperature, the actual extraction time in seconds, the batch numbers of the tea and water, the dilution factor, the absorbance, and any anomalies. When a reading is abnormal, record the reason and the handling according to rules made beforehand, keep the original record, and do not delete values because the result is not what was expected.

How to Interpret the Response Once You Have It

After obtaining the eight absorbances, fit the pre-specified six-term model, check the residuals and the anomaly records, and then interpret the fit in terms of temperature, time, and their interaction. The rank of this design matrix is 6, so eight observations correspond to 2 residual degrees of freedom; since the eight combinations are all distinct, there are 0 pure-error degrees of freedom, and a lack-of-fit test separating pure error from lack of fit cannot be carried out on this basis.

The maximal determinant means that, within the specified search space, these eight points are the most favorable for jointly estimating the six model parameters; it does not by itself provide any absorbance result, nor can it prove that the quadratic model is correct or identify the best extraction conditions. When comparing the D-efficiency of another plan, use the same basis functions, coding, and number of runs.

References

  1. [1] NIST/SEMATECH. D-Optimal designs. e-Handbook of Statistical Methods, §5.5.2.1. https://www.itl.nist.gov/div898/handbook/pri/section5/pri521.htm