Can the sensitivity and specificity reported in a diagnostic accuracy study support a systematic review’s conclusion? QUADAS-2 separates that question into two judgments: whether the study’s design and conduct could bias its accuracy estimates, and whether the study applies to the patients, test and target condition of interest to the review. A study can have a low risk of bias yet be poorly suited to the review question because its participants or the intended use of the test differ.[1][2]
QUADAS-2 is the 2011 version of a tool for assessing diagnostic accuracy studies. The University of Bristol’s QUADAS project now lists QUADAS-3 as the recommended version and QUADAS-2 as a previous version. The framework and process below describe QUADAS-2.[2][3]
Four domains, two kinds of judgment
QUADAS-2 assesses risk of bias across four domains: patient selection, index test, reference standard, and flow and timing. The first three domains also receive separate judgments about concerns regarding applicability. Signalling questions help reviewers reach the domain judgments about bias.[1][2]
Patient selection: Examine how participants were recruited and excluded. The signalling questions ask whether a consecutive or random sample was enrolled, whether a case-control design was avoided, and whether inappropriate exclusions were avoided. For applicability, compare the enrolled patients with those in the review question, including their setting, presentation, prior testing and the intended use of the index test.[1]
Index test: Record how the test was conducted and interpreted. Assess whether its results were interpreted without knowledge of the reference standard results and, if a threshold was used, whether it was specified in advance. For applicability, consider whether the test, its conduct and its interpretation match the review question. Complete this section separately for each index test used in a study.[1]
Reference standard: Consider whether the method used to establish the target condition is likely to classify it correctly and whether its results were interpreted without knowledge of the index test results. The applicability judgment asks whether the target condition defined by the reference standard matches the condition of interest to the review.[1]
Flow and timing: Trace participants through testing and analysis. Assess whether the interval between tests was appropriate, whether all patients received a reference standard, whether they received the same standard, and whether all were included in the analysis. This domain receives a risk-of-bias judgment but no separate applicability judgment.[1][2]
How to use the tool in a review
First, state the review question: identify the target patients and setting, the intended use of the index test, the reference standard and the target condition. This provides the point of comparison for applicability and guides the details to extract from each study.[1][2]
Second, tailor the tool and prepare review-specific guidance. For example, specify in advance which intervals between tests could allow the condition to change, which exclusions matter to the question, and how those details will inform judgments. Reviewers can independently pilot the tool on several studies, discuss disagreements and refine the guidance before applying it consistently.[2]
Third, map patient flow through each primary study. Start with the number enrolled, then record how many received the index test and reference standard, their sequence and interval, and the number and reasons for exclusion from the accuracy analysis. A flow diagram helps identify missing results and different verification pathways.[1][2]
Fourth, answer the signalling questions and make domain judgments. Signalling questions are answered “yes”, “no” or “unclear”; risk of bias in each domain and applicability concerns in the first three are judged “low”, “high” or “unclear”. Record the study information and reasoning behind each judgment so the basis for it remains visible.[1][2]
An illustration: two questions about one study
Suppose a review concerns the accuracy of a test used for the first time in symptomatic patients in primary care. A study consecutively recruits patients at a specialist centre, interprets the test using a prespecified threshold and interprets the reference standard without knowledge of the index test result. However, it includes only patients referred after other investigations. If the report supports these descriptions, reviewers can assess risk of bias in the relevant domains; concern about the applicability of patient selection may still be high because the enrolled population differs from the primary-care population in the review. Record the population difference and the reason for the applicability judgment separately.
Now suppose only some patients with a negative index test receive the reference standard, and the study does not explain how they were selected. In the flow and timing domain, record which patients did not receive the reference standard and use the prespecified guidance to judge whether this could affect the accuracy estimate. If the report lacks information needed for the judgment, mark it “unclear” and record what is missing.[1]
Using the results
Present the four risk-of-bias judgments and three applicability judgments for each study, with their key supporting information. Then explain which domain concerns may affect the review’s conclusions. Where enough studies are available, relevant judgments can also inform stratified or sensitivity analyses to explore whether conclusions change. QUADAS-2 identifies where problems may arise; a total quality score cannot replace the domain judgments.[1][2]