Researchers have a batch of records to analyze but can afford manual labeling for only some of them. Active statistical inference uses existing predictions to preferentially sample the more informative records, then corrects the estimate with true labels. But if each record independently decides by probability whether to enter the sample, the final number of labels fluctuates: an average of 1000 draws does not mean exactly 1000 draws every time.[1][2]
In their 2026 paper, Erik Skalnes and Michael Oberst bring conditional Poisson sampling, long used in survey sampling, into this inference framework. It retains a design in which different records have different inclusion probabilities while fixing the sample size. The authors prove that, under the same target inclusion probabilities and the paper's asymptotic conditions, the asymptotic variance of conditional Poisson sampling is no larger than that of ordinary Poisson sampling; how large the gap is depends on the relationship between prediction error and sampling probability.[1]
Lay the groundwork with predictions, then correct with labels
Suppose the goal is to estimate the mean of some outcome over a candidate list. The researchers first obtain a cheaper prediction for every record on the list, and then choose a portion of the records to get true labels. The basis for active selection can be the places where the model expects larger errors: if true values there would do the most to correct the predictions, those records are given higher inclusion probabilities.[1][2]
The generalized difference estimator of the mean can be written as: population mean estimate = (sum of all predicted values) ÷ (total number of records on the list) + Σ over labeled records of [(true value − predicted value) ÷ actual inclusion probability] ÷ (total number of records on the list). The first term uses the predictions for the whole list, and the second term uses the true labels to estimate and add back the average prediction error. With the predictor fixed and each record's actual inclusion probability known and greater than zero, this correction is with respect to the sampling design and does not require the predictions themselves to be fully accurate.[1]
The paper extends the same idea to parameters expressible through estimating equations, including some regression coefficients: first build the estimating equation from the predictions, then correct the equation with the true values of the sampled records. In this framework, choosing which records to label and how to use predictions to correct bias are two interlocking parts that can be discussed separately.[1]
Calibrate the probabilities before fixing the sample size
Ordinary Poisson sampling assigns each record an inclusion probability and independently decides whether it enters the sample. The sum of these probabilities equals the expected sample size, but the number actually drawn each time may be above or below the budget. Conditional Poisson sampling instead conditions on the event "exactly the specified number is drawn," giving a design with a fixed sample size in which records are not drawn repeatedly.[1]
There is a key difference here: the coin-flip probabilities before conditioning are usually not the actual inclusion probabilities after conditioning. As an arithmetic example with two records, suppose the goal is to select exactly one, with target inclusion probabilities of 0.8 and 0.2 for the two records. If we draw independently with 0.8 and 0.2 directly, and then keep only the cases in which exactly one is selected, the first record's final inclusion probability becomes 0.8×0.8÷(0.8×0.8 + 0.2×0.2), about 94.1%, not 80%.
In this example, changing the underlying coin-flip probabilities to two-thirds and one-third gives target probabilities of 0.8 and 0.2 only after conditioning. In general, one needs to back out the underlying parameters from the target inclusion probabilities; the paper adopts an existing probability calibration method and implements fixed-size sampling with dynamic programming. After the true labels are obtained, the denominators in the estimator should use the calibrated actual inclusion probabilities.[1]
Once the sample size is locked, whether records enter the sample is no longer independent: the more records already selected, the fewer slots remain for the later ones. So besides swapping the sampling procedure, computing standard errors and confidence intervals also requires a variance estimate suited to the conditional Poisson design.[1]
Which part of the variance does a fixed size remove
The paper compares two sampling designs that use the same predictor, the same set of target inclusion probabilities and the same estimator. Under conditions such as the population and the budget growing together, the sampling fraction tending to a fixed value strictly between zero and one, and the inclusion probabilities staying away from zero and one, the authors prove that the asymptotic variance of conditional Poisson sampling is no larger than that of ordinary Poisson sampling. For multiple parameters, the conclusion corresponds to a comparison of asymptotic covariance matrices.[1]
Intuitively, the sample size under ordinary Poisson sampling varies from draw to draw; if the estimation error also varies with the sample size, fixing the sample size removes the part of the asymptotic variance that is linearly related to the count. Taking the mean as an example, what determines the gap is not how large the prediction error is by itself, but whether "true value minus predicted value," weighted by each record's probability of not being sampled, deviates from zero on average.[1]
If this weighted average is zero, the asymptotic variances of the two designs can be the same; if it deviates from zero, conditional Poisson sampling has the opportunity to bring a more noticeable improvement. Even if the predictions' population-average error is zero, the relationship between the error and the inclusion probability can still make the weighted average nonzero. Judging the benefit therefore requires looking at both the prediction residuals and the selection rule.[1]
Gaps in simulation and real data
The authors compared simple random sampling, ordinary Poisson sampling and conditional Poisson sampling. Table 1 of the paper uses 5000 random seeds, examines budgets of 100, 300, 500, 700 and 1000 labels respectively, and then aggregates the results across budgets; the comparison metrics include root mean squared error (RMSE) and expected confidence interval width. The percentages below are relative changes after aggregating across budgets in the table.[1]
In one set of simulated data, the authors made the predictor uniformly one unit higher than the correct prediction and gave all records the same target inclusion probability. The RMSE of conditional Poisson sampling is about 30% lower than that of ordinary Poisson sampling; because conditional Poisson sampling then coincides with equal-probability fixed-size sampling, its result is close to that of simple random sampling. When the predictor has no such systematic offset, the RMSE difference between the two Poisson designs is small.[1]
In one set of experiments based on 2019 American Community Survey data, the authors trained an income predictor and a residual predictor with California data, and then designed sampling for income estimation in other states. Compared with ordinary Poisson sampling, conditional Poisson sampling has an RMSE about 3% and 4% lower in Alabama and Oregon, respectively; in Massachusetts and Texas, the RMSE difference did not reach the authors' significance criterion.[1]
A fixed sample size also cannot repair a poor set of selection probabilities. On Pew post-election survey data, the authors artificially raised the logit of the original predictor and used this offset predictor both to assist estimation and to set the selection probabilities. In the experiment on support for Trump, the RMSE of conditional Poisson sampling is 13% lower than that of ordinary Poisson sampling, yet 86% higher than that of simple random sampling that also uses prediction-based correction. The offset here is an experimental condition constructed by the researchers, not a measurement of any model in actual operation.[1]
In the original active statistical inference experiments the paper reuses, the RMSE of conditional Poisson sampling differs from that of ordinary Poisson sampling by no more than 2% in all four data sets, and none of the differences reached the authors' significance criterion. In the AlphaFold scenario, the nominal coverage of the conditional Poisson interval is 90% and the aggregate coverage is 86.4%, with similar coverage for ordinary Poisson sampling. When comparing interval widths, the coverage performance is also part of the experimental result.[1]

Figure 1 | Simulation comparison in the paper: under different sample budgets, the left panel compares two population means and the right panel compares unbiased and biased predictors; the vertical axis is the expected interval width. Colors and line styles indicate the sampling design and the simulation condition. Source: Skalnes and Oberst (2026), Figure 1, CC BY 4.0. License
How to fit it into a study design
In implementation, first determine the list to be inferred, the labeling budget, and the predictions available for the whole list; then, according to the estimation target and the information at hand, design each record's target inclusion probability so that the probabilities sum to the budget. Existing labels or an independent pilot sample can be used to evaluate prediction residuals and selection scores, and part of the probability can also be allocated to uniform sampling to reduce the risk of over-relying on wrong scores.[1][2]
After sampling, keep each record's prediction, actual inclusion probability, sampling outcome and the label obtained, and use this information to compute the weighted correction. The paper's finite-population experiments use design-based Wald confidence intervals and, for conditional Poisson sampling, an approximate variance estimator based on first-order inclusion probabilities. If the target extends from this fixed list to a larger population that generated the list, the fluctuation from generating the population must also be accounted for in inference.[1]
The paper's authors also provide a Python package, cps-sampling. Its project description covers calibration of target inclusion probabilities, fixed-size sampling and variance estimation; the paper notes that the dynamic programming requires an up-front investment in computation and storage, but the same prepared results can be used in subsequent sampling.[1][3]
References
-
[1] Erik Skalnes, Michael Oberst. Fixed-Size Active Statistical Inference. 2026-10-19.
-
[2] Tijana Zrnic, Emmanuel J. Candès. Active Statistical Inference. 2024.
-
[3] Erik Skalnes. cps-sampling. 2026-10-16.
-
Research Methods · Rituals can be imitated; understanding cannot be faked.
-
Compiled and published by the Scholay All-in-One Academic Platform. If any infringement is found, please let us know and the item will be taken down.
-
Also published at EnterScholar, the scholar community for the age of intelligence.