You want to compare four treatments, but the experiment has to be done in three batches. How do you avoid mistaking batch differences for treatment effects? One approach is to make every batch contain all four treatments and compare results within each batch. The main comparisons between treatments then happen among experimental units that share the same batch conditions, rather than setting treatment A in the first batch directly against treatment B in the third.[1]

First Decide What Constitutes a Batch

The experimental design handbook of the U.S. National Institute of Standards and Technology (NIST) gives a semiconductor manufacturing example: an engineer wants to study the effect of four doses of a wafer implant material on resistivity after diffusion. The experimental wafers come from the same lot of raw material, with three wafers prepared for each dose, twelve in all. Ideally, all twelve wafers could go into the furnace together, but the production schedule allows only a few experimental wafers per furnace run.[1]

The treatment factor of interest here is the implant dose, and the measured outcome is the wafer's resistivity after diffusion; each furnace run is the batch factor that needs to be controlled. Process conditions may differ between runs. If the first run handled only low doses and later runs only high doses, the difference measured would mix dose with furnace run, and the two could not be separated from this data.[1]

Suppose each run can hold four experimental wafers. Then one furnace run can serve as a block: three runs with four wafers each, and each of the four doses taking one wafer per run. Each wafer is the unit that receives a dose treatment and is measured; wafers in the same run share that run's conditions. The three runs thus provide three sets of within-run comparisons, and the twelve wafers provide twelve observations.[1]

Furnace run (block) Dose A Dose B Dose C Dose D
Run 1 1 wafer 1 wafer 1 wafer 1 wafer
Run 2 1 wafer 1 wafer 1 wafer 1 wafer
Run 3 1 wafer 1 wafer 1 wafer 1 wafer

The table shows the allocation of treatments to furnace runs; it does not represent loading order, nor are these measurement results.

The point of this table is not that each dose gets three wafers in total, but that every run contains all four doses. If one run as a whole pushes resistivity higher, all four wafers in that run are under that run's conditions; when two wafers from the same run are compared, the shared run effect no longer directly stands in for a difference between two doses. A block design exploits this within-batch comparison; it does not require the runs themselves to be identical.

After Completing the Set, Randomize the Assignment

“One of each in every run” specifies the allocation, but does not yet decide which wafer receives which dose. If the twelve wafers have not yet been treated, a randomization table generated in advance can be used to assign the four wafers of each run to doses A, B, C and D, and the next run is then arranged independently, until all three runs are done. If wafers for each of the four doses have already been prepared, three per dose, then as in the NIST example, the three wafers within each dose can be randomly assigned to the three furnace runs.[1]

In execution, the assignment table should at least link wafer ID, dose and furnace run, and record the run actually entered and the resistivity measured. If position within the furnace may affect results, positions can be randomized and recorded beforehand; if a wafer is damaged or a measurement fails, keep the original assignment and the failure record rather than quietly deleting it and treating another wafer as the original unit. Only then can each within-run comparison be traced according to what actually happened.

Blocking and randomization play different roles: putting four doses into the same run actively controls a known and important run-to-run difference; randomizing the assignment within the allocation guards against systematic bias from the researcher choosing wafers or positions in a fixed way. NIST summarizes the principle concisely: block on the factors that can be blocked, and leave the other, uncontrollable factors to randomization.[1]

Compute Within-Run Differences First, Then Pool

Consider a set of illustrative numbers. Suppose the resistivity for dose A in the three runs is 100, 110 and 120, and for dose B is 103, 114 and 122, all in Ω·cm. These numbers are only to illustrate the calculation: B minus A in each run is 3, 4 and 2 Ω·cm, and the mean of the three within-run differences is (3 + 4 + 2) ÷ 3 = 3 Ω·cm. For these three runs, the mean difference of B relative to A is 3 Ω·cm.

Although the overall level rises from about 100 to about 120 across the three runs, the within-run difference stays around 3. Within each run, the run-level effect that the two wafers share cancels on subtraction; averaging the three differences gives the mean dose difference over the runs selected. An experiment with four doses can construct the comparisons of interest in the same way, such as B minus A, C minus A and D minus A, while retaining the results of each run.

To analyze all four doses, a model with a dose term and a furnace-run term can be used: Yᵢⱼ = μ + Tᵢ + Bⱼ + errorᵢⱼ. Yᵢⱼ is the resistivity of dose i in run j, μ is the overall level, Tᵢ is the dose term, and Bⱼ is the furnace-run term. The model lists the shared run-to-run variation separately and then estimates differences between doses; the NIST handbook gives exactly this basic model in which a treatment term and a block term are added.[1]

Confirm Capacity and Comparison Goals Before Scheduling

Whether the design is feasible depends first on whether one run can hold all the treatments. With four doses and four wafers per run, each run takes exactly one of each; if each run can hold only two wafers, a complete block cannot be formed as is. In that case, batch capacity, the number of treatments, or a different suitable design should be reconsidered before the experiment, rather than treating incomplete two-wafer runs afterwards as the table above.

You should also write down in advance the dose comparisons you care most about, the measurement method, and how many independent furnace runs are needed. A three-run layout makes every dose appear across three runs, but each “dose × run” cell holds only one wafer. Measuring the same wafer several times within a run can supply repeated-measurement information, but it does not add independent runs and cannot be counted as more independent wafers.

When scheduling, first draw the furnace runs as columns and the treatments as rows and check that every column is complete; then generate the randomization table and record wafer, dose, furnace run and measured value. Analysis starts from within-run comparisons and then combines the results across runs. The experiment therefore need not rely on the supposition that “every run is the same”; instead, the design lets the different doses go through every furnace run together.

References

  1. National Institute of Standards and Technology. 5.3.3.2. Randomized block designs. Undated.

  2. Research Methods · Rituals can be imitated; understanding cannot be faked

  3. Compiled and published by the Scholay all-in-one academic platform. Please contact us to have it taken down in case of infringement.

  4. Also published at Enter Scholar, a scholar community for the age of intelligence