When the label distribution in the target data differs from that in the training data, the standard originally used to judge whether a predicted value is reasonable may also be biased toward the source data. Lee et al. propose the Label-Shift-Adjusted Bayesian Score (LSA): first adjust the predictive distribution, then perform weighted conformal calibration using the adjusted nonconformity scores. It addresses the efficiency of regression prediction intervals under label shift, rather than retraining the whole predictive model. The paper's experiments show that intervals can be shortened, but the coverage gap caused by estimated weights remains. [1]

First Change the Predictive Distribution, Then Evaluate Candidate Labels

Label shift here means that the marginal label distributions of the source and target domains differ, while the distribution of the feature representation given the label stays the same, that is, p_s(h|y) = p_t(h|y). This differs from the condition usually used under covariate shift, where the conditional relationship p(y|x) stays unchanged. The paper's prediction-level identity also requires that the corresponding conditional mechanism remain unchanged after the source model is fitted, that the target label distribution be absolutely continuous with respect to the source label distribution, and that the source predictive model satisfy a representativeness condition. When these assumptions hold, the target predictive density can be obtained by multiplying the source predictive density by the label density ratio and then normalizing: [1]

r(y)=pt(y)ps(y),pt(y∣h)=ps(y∣h)r(y)Z(h),Z(h)=∫ps(u∣h)r(u) du.r(y)=\frac{p_t(y)}{p_s(y)},\qquad p_t(y\mid h)=\frac{p_s(y\mid h)r(y)}{Z(h)},\qquad Z(h)=\int p_s(u\mid h)r(u)\,du.

The density ratio measures how common a label is in the target domain relative to the source domain; the normalizing term makes the predictive density for each input integrate to 1. The plausibility of a given candidate label therefore depends not only on how much probability the source model gives it, but also on how strongly it is favored in the target domain. This identity is the starting point of the method; it does not mean that whenever the label marginal changes, any source model automatically yields an exact target prediction. [1]

Denote the negative log of the source predictive density as the source score s_s(h,y), and replace the unknown density ratio with an estimate r̂; the LSA score is then s_LSA(h,y) = s_s(h,y) − log r̂(y) + log Ẑ(h). Labels favored in the target domain receive a lower nonconformity because of −log r̂(y); Ẑ(h) completes the input-dependent normalization. The lower the score, the better the candidate label agrees with the adjusted predictive distribution. [1]

The paper gives an analytically tractable implementation using Bayesian ridge regression: the source prediction is a Gaussian distribution with mean μ(h) and variance σ²(h), and the estimated density ratio takes the form log r̂(y) = β̂₀ + β̂₁y. The tilted prediction is still Gaussian, with the mean becoming μ*(h) = μ(h) + β̂₁σ²(h) and the variance remaining σ²(h). The same shift slope therefore produces a larger center adjustment for inputs with larger predictive variance. [1]

Two panels comparing Gaussian density curves before and after tilting, and negative log score curves

A known tilted-Gaussian example following the paper's tilting identity: source mean 0, standard deviation 1.4, η = 0.6, target mean 1.176; the left panel shows densities and the right panel shows scores. It computes only the identity; it is not an empirical reproduction of LSA or a conformal coverage experiment.

The known density ratio in the figure is proportional to exp(0.6y): the positive tilt moves the predictive density toward larger labels, and the log of the normalizing term is 0.3528. The right panel also shows how the score changes with the density. This example explains the algebraic transformation of the predictive distribution; how wide the interval finally is must still be determined through the calibration step.

Scoring and Calibration Weighting Are Two Different Adjustments

What LSA changes is how each candidate label is scored. After that, the method also uses r̂(y_i) to weight the source-domain calibration samples when computing the empirical quantile of the scores: labels that are relatively common in the target domain receive more weight when the calibration samples are aggregated. The first step changes the nonconformity being measured, and the second changes how the calibration samples are aggregated; both use the density ratio, but they should not be regarded as the same operation. [1]

The paper divides the data into four non-overlapping parts: training, weight estimation, calibration, and target evaluation. The source model's predicted means serve as pseudo-labels for the target data and are used to estimate the density ratio; when computing the weighted quantile, the test point's weight also uses its pseudo-label. After the threshold is obtained, the prediction interval is centered at μ*(h), and its width is determined jointly by the threshold and σ(h). [1]

This is not shifting a fixed-length residual interval as a whole. The residual score that the paper compares produces intervals of uniform length, whereas both the Source score based on the source predictive density and the LSA score can adjust the interval width according to predictive uncertainty. The difference between the two is that LSA also adjusts the predictive center on which scoring is based according to the estimated label shift. [1]

Intervals Get Shorter, but the Coverage Guarantee Does Not Follow Automatically

On AqSolDB molecular aqueous-solubility data, the paper constructs a controlled exponential tilt: the target test set is sampled with replacement with probability proportional to exp(βy), with β varying from 0 to −0.5; the target coverage is set to 90%, and each setting is repeated over 1000 random seeds. The three methods share the Bayesian ridge regression predictive model, the weight estimator, and the weighted quantile computation, and the main difference is the nonconformity score. [1]

The paper reports that at β = −0.5, LSA has a mean interval length of 4.977, the Source score 5.744, and the residual score 5.820; the mean coverages are 0.8842, 0.8795, and 0.8797, respectively. LSA's intervals are shorter and its coverage is similar to that of the two baselines, but all three fall below the 0.9 target. As the shift strengthens, the paper observes that the coverage of all three methods declines. [1]

Here it is necessary to distinguish the predictive-density identity from the coverage guarantee of the complete conformal procedure. Even under the paper's assumptions, a known true density ratio can yield the target predictive score, but the actual procedure must still estimate the density ratio from pseudo-labels and approximate the test point's weight using pseudo-labels. The authors therefore do not claim that the method has exact finite-sample validity under label shift. Correcting the predictive distribution provides a scoring approach that fits the target domain better; how estimation error affects the weighted calibration still determines the actual coverage performance. [1]

The contribution of this work is to write the effect of label shift on the predictive distribution directly into the conformal score, and to show, within the same weighted calibration framework, the interval-efficiency gains it can bring. In application, look at both interval length and target-domain coverage: a shorter interval is a valuable result, but one cannot infer an exact coverage guarantee from the score identity or from similar coverage performance alone.

References

  1. [1] Hyeonsu Lee, Juyeon Kim, Erkhembayar Jadamba, Seungjin Choi, Hyunjin Shin. Split Conformal Prediction with Label-Shift-Adjusted Bayesian Scores. arXiv:2609.12386v1, 2026-09-11. https://arxiv.org/pdf/2609.12386