A new instrument's readings correlate highly with an old one's—can it replace the old instrument? What matters is how far the two results differ for the same person, and whether that gap would change a practical judgment. A Bland–Altman plot draws each pair's difference on its own so that question can be inspected directly.[1]
High correlation, still possibly large differences
In 1986, J. Martin Bland and Douglas G. Altman illustrated the point with readings from two peak expiratory flow meters. Seventeen colleagues and relatives used a large Wright peak-flow meter and a mini Wright meter, each instrument twice; for the method comparison they took each person's first reading on each instrument. The correlation between the two sets of readings was 0.94—apparently strong—yet that does not say how far the two instruments differ for the same person.[1]
Correlation measures whether two sets of numbers move together. If one method's reading were always twice the other's, the linear correlation could still be perfect, but the readings clearly could not be mixed directly. Comparing measurement methods requires shifting attention from “do the values rise and fall together?” to “how far apart is each pair?”[1]
One pair of readings becomes one point on the plot
For each participant, fix the subtraction order: large-meter reading minus mini-meter reading for the difference; then average the two readings for the mean. With mean on the horizontal axis and difference on the vertical, each person is one point. A negative vertical coordinate means the large meter read lower in that pair; a positive one means higher.
In the paper's table, the first participant read 494 L/min on the large meter and 512 L/min on the mini. The mean is (494+512)÷2=503 L/min and the difference is 494-512=-18 L/min, so the point sits at horizontal 503 and vertical −18. Repeating for the other 16 pairs shows how differences spread across the measurement range.[1]
The first reference line on the plot is the average of all differences, also called the mean difference or bias. In the example the mean difference is −2.1 L/min, meaning that among these 17 first-reading pairs the large meter averaged 2.1 L/min lower than the mini. Near zero does not mean every person's difference is near zero: positive and negative differences can cancel in the average.[1]
Limits of agreement describe the range of differences
Next compute the sample standard deviation s of the differences, which describes how the pair differences scatter around the mean difference. When differences are approximately normal and their distribution does not change markedly with measurement level, “mean difference ±1.96s” estimates the range covering about 95% of paired differences; those bounds are the limits of agreement. For ease of calculation the original paper used the approximation “mean difference ±2s”.[1]
For this data set the mean difference is −2.1 L/min and the sample SD of differences is 38.8 L/min. Following the paper's approximate algorithm:[1]
- lower bound: −2.1-2×38.8=−79.7 L/min;
- upper bound: −2.1+2×38.8=75.5 L/min.
Interpreted in the “large minus mini” order, this estimated range runs from the large meter about 80 L/min lower than the mini to about 76 L/min higher. Drawing horizontal lines at the mean difference and the two bounds shows overall bias and the scatter of individual differences together. These limits describe differences between paired readings; they are not a confidence interval for the mean difference.[1]

Figure 1|Difference plot recomputed from the 17 original reading pairs, with limits at mean difference ±2SD. The figure uses unrounded data; values in the text use the paper's rounded figures and differ by about 0.1. Green marks an illustrative ±10 L/min judgment band. Data: Bland and Altman (1986) Table 1, redrawn here. Original data table[1].
Compare statistical limits with an acceptable difference
Limits of agreement are estimated from the data; an acceptable difference is set by the use of the measurement. Before looking at results, researchers should decide the allowed difference range in light of how readings will affect judgment. For example, the paper uses 10 L/min to illustrate a very small difference: if a use case allows only ±10 L/min in advance, the example's roughly −80 to +76 L/min limits clearly exceed that requirement.[1]
Thus the plot does not automatically answer “can they substitute?” with one rule. The same set of differences may matter differently for coarse classification than for decisions near a tight threshold. Judgments should look both ways: reading high and reading low can have different consequences.
Also ask how precisely the limits themselves are estimated. For these 17 pairs the paper gives approximate 95% confidence intervals of −114.3 to −45.1 L/min for the lower limit and 40.9 to 110.1 L/min for the upper. The intervals are wide, so another sample could move the estimated limits substantially. If point estimates of the limits appear to fall just inside an acceptable range, their confidence intervals may still cross that range—so conclusions cannot rest on the two point-estimate lines alone.[1]
Look at the shape of the points, not only the three lines
After plotting, first see whether differences change with measurement level. If points rise from left to right, the mean difference may change with reading size; if the cloud fans out, differences are more dispersed at high readings. Then a single pair of fixed horizontal limits for the whole range may overstate differences at low values and understate them at high values.[1]
If readings are all positive and differences are better understood in relative than absolute terms, one may take logarithms first and analyze log-differences. After transforming back to the original scale, the limits express a range of ratios between the two readings. For example, ratios 0.80 to 1.27 mean one reading is about 80% to 127% of the other. After the transform, still check the plot to confirm that the pattern of differences improved.[1]
Finally, how much the same instrument fluctuates on repeat measurement also limits how close two methods can agree. If the old method already varies a lot on the same subject, even a more stable new method may not match it on single readings. The original paper therefore examined repeatability on each meter separately: method comparison says how far the two readings differ; repeatability analysis helps explain where those differences come from.[1]
References
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. 1986.
-